Electrical wiring is the method of attaching different accessories for the delivery of electrical energy from the supplier's metre board to home appliances such as lamps, fans, and other domestic appliances. The type of service needed will have a big impact on the wiring system you choose.
The most common forms of internal wiring are:
> Cleat wiring
> Wooden casing and capping wiring
> CTS or TRS or PVC sheath wiring
> Lead sheathed or metal sheathed wiring
> Conduit wiring
We will be discussing the CTS or TRS or PVC sheath wiring in this answer. Therefore,
CTS or TRS or PVC sheath wiring (Batten wiring):
In this form of wiring, single core, double core, or three core TRS cables with a circular oval shape are used. Single-core cables are most commonly used. TRS cables are chemical, water, and steam resistant, but lubricating oil has a minor effect. TRS cables are mounted on well-seasoned, straight teak wood battens with a minimum thickness of $10mm$.
The cables are held on the wooden batten by tinned brass connection clips (buckle clips) that are already fixed on the batten with brass pins and spaced at a $10cm$ horizontal run interval and $15cm$ vertical run interval.
Now, we will look upon the advantages of these wiring:
> When opposed to other electrical wiring schemes, wiring installation is simple and inexpensive.
> It's both nice and beautiful.
> This wiring system is simple to repair, sturdy, and long-lasting. It also allows for easy customization.
> In a batten wiring scheme, there is a lower risk of current leakage.
The disadvantages of such wiring schemes are:
> Humidity, chemical impact, open and outdoor areas are not suitable for installation.
> There is a high chance of fires.
> Since the wires are exposed to fire, dust, steam, and smoke, they are not resistant to external wear and tear or weather effects.
> In a batten wiring scheme, heavy wires are not permitted.
> Only suitable for use below $250V$.
> More cables and wires are needed.
Note:
It is very important to note that the type of wiring scheme which is used totally depends on the purpose of the wiring. The wiring schemes used in the residential and the commercial buildings fans, lights, pumps and other domestic appliances is known as domestic wiring whereas, the wiring schemes used for the purpose of operating the industrial equipment which require a very heavy power load is known as industrial wiring.
Complete step by step solution:
Electrical wiring is the method of attaching different accessories for the delivery of electrical energy from the supplier's metre board to home appliances such as lamps, fans, and other domestic appliances. The type of service needed will have a big impact on the wiring system you choose.
The most common forms of internal wiring are:
> Cleat wiring
> Wooden casing and capping wiring
> CTS or TRS or PVC sheath wiring
> Lead sheathed or metal sheathed wiring
> Conduit wiring
We will be discussing the CTS or TRS or PVC sheath wiring in this answer. Therefore,
CTS or TRS or PVC sheath wiring (Batten wiring):
In this form of wiring, single core, double core, or three core TRS cables with a circular oval shape are used. Single-core cables are most commonly used. TRS cables are chemical, water, and steam resistant, but lubricating oil has a minor effect. TRS cables are mounted on well-seasoned, straight teak wood battens with a minimum thickness of $10mm$.
The cables are held on the wooden batten by tinned brass connection clips (buckle clips) that are already fixed on the batten with brass pins and spaced at a $10cm$ horizontal run interval and $15cm$ vertical run interval.
Now, we will look upon the advantages of these wiring:
> When opposed to other electrical wiring schemes, wiring installation is simple and inexpensive.
> It's both nice and beautiful.
> This wiring system is simple to repair, sturdy, and long-lasting. It also allows for easy customization.
> In a batten wiring scheme, there is a lower risk of current leakage.
The disadvantages of such wiring schemes are:
> Humidity, chemical impact, open and outdoor areas are not suitable for installation.
> There is a high chance of fires.
> Since the wires are exposed to fire, dust, steam, and smoke, they are not resistant to external wear and tear or weather effects.
> In a batten wiring scheme, heavy wires are not permitted.
> Only suitable for use below $250V$.
> More cables and wires are needed.
Note:
It is very important to note that the type of wiring scheme which is used totally depends on the purpose of the wiring. The wiring schemes used in the residential and the commercial buildings fans, lights, pumps and other domestic appliances is known as domestic wiring whereas, the wiring schemes used for the purpose of operating the industrial equipment which require a very heavy power load is known as industrial wiring.
Recently Updated Pages
Master Class 12 Economics: Engaging Questions & Answers for Success

Master Class 12 Maths: Engaging Questions & Answers for Success

Master Class 12 Biology: Engaging Questions & Answers for Success

Master Class 12 Physics: Engaging Questions & Answers for Success

Basicity of sulphurous acid and sulphuric acid are

Master Class 9 General Knowledge: Engaging Questions & Answers for Success

Trending doubts
Give 10 examples of unisexual and bisexual flowers

Draw a labelled sketch of the human eye class 12 physics CBSE

a Tabulate the differences in the characteristics of class 12 chemistry CBSE

Differentiate between homogeneous and heterogeneous class 12 chemistry CBSE

Why is the cell called the structural and functional class 12 biology CBSE

Differentiate between insitu conservation and exsitu class 12 biology CBSE