

What is a Geiger Counter?
A lot of modern applications require working in the presence of high radioactive substances. If adequate safety measures are not taken, then radiation can have a very detrimental effect on the health of people. The horrors of Chernobyl will always be a reminder for humanity that radioactive energy is a force to be reckoned with.
Therefore, to assess levels of radiation so it does not cause us harm, a device called a Geiger Counter is used. This device is used in the detection and measurement of radiation in ionized substances. This has numerous applications in the field of research and medicine.
History of Geiger Counter
Hans Geiger in 1908, under the supervision of Ernest Rutherford, developed an experimental technique for detecting alpha particles which became the basis for developing the Geiger–Müller tube in 1928. The basic ionization mechanism used was discovered by John Sealy Townsend between 1897 and 1901 and is known as the Townsend discharge.
(Image will be Uploaded Soon)
Geiger and Walther in 1928 developed the sealed Geiger–Müller tube which they used. It was so small, rugged that not only could it detect alpha-beta radiation both, but also gamma radiation. So radiation-instruments could be produced relatively cheaply, and so the Geiger counter came into existence.
What is the use of Geiger Counter?
A Geiger Counter is an instrument which is used for detecting and measuring ionizing radiation. It is also known as a Geiger–Muller counter; this is widely used in many applications like experimental physics, radiological protection, radiation dosimetry, nuclear industry and nuclear-industry.
(Image will be Uploaded Soon)
It detects ionizing-radiation such as alpha particles, beta particles and gamma particles using the ionization effect produced in the Geiger Muller tube by which the name of the instrument is known.
What Principle does a Geiger Counter Work on?
This device consists of a Geiger-Muller tube, which contains a noble gas (usually helium or argon) at a very low pressure, possibly the lowest. Under the application of a relatively high voltage, the electrical change would indicate radiation if the gas becomes conducive. It can be used to detect all kinds of radiation- alpha, beta and gamma.
The modern type of Geiger Counter uses the halogen tube, and these lightweight instruments offer an improvement. Better range of detection of multiple types of ionizing radiation, i.e. alpha, beta, X-rays, and gamma, all are available even in the same unit. Their features are easy to use, common-interface and compatible with a catalogue of optional accessories for wireless reach back, rechargeable batteries, and extension poles to maintain good ALARA (as low as reasonably achievable) principles.
Types and Applications of Geiger Counter
An intended-detection application of a Geiger Counter explains the tube design being used. Subsequently, there are many designs which may be generally categorized as end-window, or windowless also as thin-walled or thick-walled, and sometimes hybrids of these types.
Historical uses of the Geiger principle was for the alpha and beta particles detection. However, this instrument is still being used for this purpose today. Geiger Counter shares wide applications as they are used as handheld radiation survey instruments and is probably one of the world's best instruments known for radiation detection.
Some applications of a Geiger Counter are as follows:
Detection of radioactive rocks and minerals in mining.
For first responders such as firemen and hazard management personnel to ensure that the site is clear of radiation.
Ensuring that levels of radiation are within permissible levels around nuclear power plants.
Detection of radiation in scrap metal processing industries.
Detection of radiation in erstwhile warzones.
Ensuring that patients undergoing radiation therapy are not overexposed to radiation.
Ensuring that uranium mines and surrounding areas do not become overly radioactive.
(Image will be uploaded soon)
The "end-window" type of a GM tube has to be used for alpha particles, and low energy beta particles as the particles show a limited range and are easily stopped by the solid-material. Therefore, this tube requires a window which is thin enough to allow as many as possible of these particles. The window is usually made of mica with1.5 - 2.0 mg/cm2 density.
Alpha particles contain the shortest range, and to detect these the window should ideally be less than 10 mm of the radiation source. Geiger–Müller tube generates a pulse output that is the same magnitude for all radiations detected, hence the Geiger counter with an end window tube is not able to distinguish the alpha or beta particles.
The "pancake" GM tube is a type of end-window probe and designed with a larger detection area for quick checking. However, Atmospheric pressure against fill gas's low pressure minimizes the window size because of the limited strength of the membrane.
(Image will be Uploaded Soon)
Some beta-particles can also be detected by thin-walled "windowless" GM tubes that have no end-window, however, allow high energy beta-particles to pass through the tube. The tube walls have more stopping power in comparison to a thin end-window; they even allow these energetic particles to reach the fill gas.
‘End-window’ GM counters are still being used as a portable, general-purpose, radioactive-contamination measurement and detection-instruments, due to their less cost, robustness and high detection-efficiency especially with energy-rich beta particles.
For differentiation between alpha and beta particles and to know the particle's energy information, the scintillation counters are used.
Points To Note:
Detected radiation readout method in Geiger counter are of two types, i.e. Counts and Radiation dose. There is a simple type of display unit which shows the number of ionizing events detected displayed as a count rate, like "counts per minute or seconds" or as the total number of counts over the set period.
This count readout is usually taken when alpha particles or beta particles are being detected normally. To achieve a display of radiation-dose rate is more complicated. It displays in Sievert, normally used to measure gamma or X-ray dose rates.
Presence of radiation can be detected by a GM tube, not its energy, that influences the radiation's ionizing effect. The electronic processor will apply only known factors to make this conversion, i.e., specific to every instrument and is determined by its design & calibrations.
The readout may be analogue or digital, and the modern instruments provide serial communications with a host network or computer. The option is there to generate audible clicks that represent ionization events. It is the distinctive sound normally seen with handheld or portable Geiger counters.
Advantages of a Geiger Counter
The benefits of using these devices are mentioned as follows:
They can prevent nuclear accidents by always giving a reading of radiation levels. Since radiation cannot be seen, it is otherwise impossible to know if the levels at a place have become hazardous.
They are used to ensure safety in all operations that require working with radioactive material.
They are highly sensitive devices, therefore the readings are usually accurate.
They can be very useful in expanding the scope of nuclear energy to greater levels in order to fully harness it for the benefit of mankind.
Disadvantages of GM Counter
Below is the list of demerits as discovered by working with Geiger-Muller counter:
GM counters can not measure energy due to a lack of differentiating abilities.Uncharged particles like neutrons cannot be detected.
GM counters are less efficient due to its large paralysis time limits and also large dead-time.
Quenching agents used in GM counters often decompose, which leads to the reduction in a lifetime.
Thus, GM Counter is primarily used due to its advantages. However, GM counters are not free from disadvantages, its uses make it preferable over other radiation counters.
FAQs on Geiger Counter
1. What is a Geiger counter and what is its main purpose?
A Geiger counter, also known as a Geiger-Müller counter, is a scientific instrument used to detect and measure ionising radiation. Its main purpose is to identify the presence of radiation from particles like alpha, beta, and gamma rays in a specific area or from an object.
2. How does a Geiger counter actually work?
A Geiger counter works based on the principle of gas ionisation. It contains a sealed tube (the Geiger-Müller tube) filled with an inert gas. When a radiation particle enters the tube, it collides with a gas atom and knocks an electron off, creating an ion pair. A high voltage applied across the tube accelerates this electron, causing it to ionise more atoms, leading to a cascade of electrons called an avalanche. This creates a short electrical pulse, which is detected and converted into a 'click' sound or a reading on a display.
3. Why does a Geiger counter make a clicking sound?
The characteristic 'click' of a Geiger counter represents the detection of a single radiation particle. Each time a particle creates an electrical pulse inside the Geiger-Müller tube, the device's electronics convert that pulse into an audible click. A faster rate of clicking indicates a higher level of radiation, making it an immediate, real-time indicator of radiation intensity.
4. Can a Geiger counter detect every type of radiation?
No, a Geiger counter is not effective for all types of radiation. While it is excellent at detecting alpha and beta particles and can detect gamma rays, it has limitations. It cannot detect:
- Neutron radiation, as neutrons do not cause ionisation directly.
- Low-energy radiation that cannot penetrate the wall of the detector tube.
- Non-ionising radiation like microwaves or radio waves.
5. What is the difference between a Geiger counter and a dosimeter?
The main difference lies in what they measure. A Geiger counter measures the real-time rate of radiation (counts per second/minute) at a specific moment. A dosimeter, on the other hand, measures the total accumulated dose of radiation a person or object has been exposed to over a period of time. Think of it like a speedometer (Geiger counter) versus an odometer (dosimeter).
6. What are some common real-world applications for a Geiger counter?
Geiger counters are used in various fields for safety and research. Common applications include:
- Nuclear facilities: To monitor for radiation leaks and ensure worker safety.
- Hospitals: In nuclear medicine departments to check for contamination.
- Geology: For prospecting for radioactive minerals like uranium.
- Emergency services: To assess radiation levels after an accident or incident.
7. What are the main limitations of a Geiger counter?
Besides not being able to detect all types of radiation, Geiger counters have other drawbacks. A key limitation is the 'dead time'—a brief period after detecting one particle when the device cannot detect another. In very high radiation fields, this can cause the counter to give an inaccurate, lower-than-actual reading. They also cannot distinguish between different types of radiation (e.g., alpha vs. beta) without special modifications like different windows.
8. What kind of natural background radiation can a Geiger counter detect?
A Geiger counter can easily detect natural background radiation that is present everywhere. This radiation primarily comes from:
- Cosmic rays from space that bombard the Earth.
- Terrestrial sources, which are naturally occurring radioactive elements in rocks, soil, and water, such as uranium, thorium, and potassium.
- Radon gas, which is a radioactive gas released from the decay of uranium in the ground.

















